1.
Radiat Res ; 200(4): 357-365, 2023 10 01.
Article in English | MEDLINE | ID: mdl-37702413

ABSTRACT

Significant past work has identified unexpected risks of central nervous system (CNS) exposure to the space radiation environment, where long-lasting functional decrements have been associated with multiple ion species delivered at low doses and dose rates. As shielding is the only established intervention capable of limiting exposure to the dangerous radiation fields in space, the recent discovery that pions, emanating from regions of enhanced shielding, can contribute significantly to the total absorbed dose on a deep space mission poses additional concerns. As a prerequisite to biological studies evaluating pion dose equivalents for various CNS exposure scenarios of mice, a careful dosimetric validation study is required. Within our ultimate goal of evaluating the functional consequences of defined pion exposures to CNS functionality, we report in this article the detailed dosimetry of the PiMI pion beam line at the Paul Scherrer Institute, which was developed in support of radiobiological experiments. Beam profiles and contamination of the beam by protons, electrons, positrons and muons were characterized prior to the mice irradiations. The dose to the back and top of the mice was measured using thermoluminescent dosimeters (TLD) and optically simulated luminescence (OSL) to cross-validate the dosimetry results. Geant4 Monte Carlo simulations of radiation exposure of a mouse phantom in water by charged pions were also performed to quantify the difference between the absorbed dose from the OSL and TLD and the absorbed dose to water, using a simple model of the mouse brain. The absorbed dose measured by the OSL dosimeters and TLDs agreed within 5-10%. A 30% difference between the measured absorbed dose and the dose calculated by Geant4 in the dosimeters was obtained, probably due to the approximated Monte Carlo configuration compared to the experiment. A difference of 15-20% between the calculated absorbed dose to water at a 5 mm depth and in the passive dosimeters was obtained, suggesting the need for a correction factor of the measured dose to obtain the absorbed dose in the mouse brain. Finally, based on the comparison of the experimental data and the Monte Carlo calculations, we consider the dose measurement to be accurate to within 15-20%.


Subject(s)
Mesons , Animals , Mice , Radiometry/methods , Protons , Central Nervous System , Monte Carlo Method , Thermoluminescent Dosimetry/methods , Water , Phantoms, Imaging
2.
Rev Sci Instrum ; 86(8): 083310, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26329184

ABSTRACT

High-energy e(-) and π(-) were measured by the multichannel plate (MCP) detector at the PiM1 beam line of the High Intensity Proton Accelerator Facilities located at the Paul Scherrer Institute, Villigen, Switzerland. The measurements provide the absolute detection efficiencies for these particles: 5.8% ± 0.5% for electrons in the beam momenta range 17.5-300 MeV/c and 6.0% ± 1.3% for pions in the beam momenta range 172-345 MeV/c. The pulse height distribution determined from the measurements is close to an exponential function with negative exponent, indicating that the particles penetrated the MCP material before producing the signal somewhere inside the channel. Low charge extraction and nominal gains of the MCP detector observed in this study are consistent with the proposed mechanism of the signal formation by penetrating radiation. A very similar MCP ion detector will be used in the Neutral Ion Mass (NIM) spectrometer designed for the JUICE mission of European Space Agency (ESA) to the Jupiter system, to perform measurements of the chemical composition of the Galilean moon exospheres. The detection efficiency for penetrating radiation determined in the present studies is important for the optimisation of the radiation shielding of the NIM detector against the high-rate and high-energy electrons trapped in Jupiter's magnetic field. Furthermore, the current studies indicate that MCP detectors can be useful to measure high-energy particle beams at high temporal resolution.

3.
Nature ; 434(7037): 1098-103, 2005 Apr 28.
Article in English | MEDLINE | ID: mdl-15858565

ABSTRACT

Soft-gamma-ray repeaters (SGRs) are galactic X-ray stars that emit numerous short-duration (about 0.1 s) bursts of hard X-rays during sporadic active periods. They are thought to be magnetars: strongly magnetized neutron stars with emissions powered by the dissipation of magnetic energy. Here we report the detection of a long (380 s) giant flare from SGR 1806-20, which was much more luminous than any previous transient event observed in our Galaxy. (In the first 0.2 s, the flare released as much energy as the Sun radiates in a quarter of a million years.) Its power can be explained by a catastrophic instability involving global crust failure and magnetic reconnection on a magnetar, with possible large-scale untwisting of magnetic field lines outside the star. From a great distance this event would appear to be a short-duration, hard-spectrum cosmic gamma-ray burst. At least a significant fraction of the mysterious short-duration gamma-ray bursts may therefore come from extragalactic magnetars.

4.
Phys Med ; 17 Suppl 1: 119-23, 2001.
Article in English | MEDLINE | ID: mdl-11770526

ABSTRACT

The Proton Irradiation Facility (PIF) has been designed and constructed, in cooperation between Paul Scherrer Institute (PSI) and European Space Agency (ESA), for terrestrial proton testing of components and materials for spacecraft. Emphasis has been given to generating realistic proton spectra encountered by space-flights at any potential orbit. The facility, designed in a user-friendly manner, can be readily adapted to the individual requirements of experimenters. It is available for general use serving also in testing of radiation monitors and for proton experiments in different scientific disciplines. The Radiation Environment Monitor REM has been developed for measurements of the spacecraft radiation conditions. Two instruments were launched into space, one into a Geo-stationary Transfer Orbit on board of the STRV-1b satellite and one into a Low Earth Orbit on the Russian MIR station. The next generation of monitors (SREMs--Standard REMs) is currently under development in partnership of ESA, PSI and Contraves-Space. They will operate both as minimum intrusive monitors, which provide radiation housekeeping data and alert the spacecraft when the radiation level crosses allowed limits and as small scientific devices measuring particle spectra and fluxes. Future missions as e.g. INTEGRAL, STRV-1c and PROBA will be equipped with new SREMs.


Subject(s)
Facility Design and Construction , Materials Testing , Protons , Radiation Monitoring/instrumentation , Radiation Protection , Space Flight/instrumentation , Atlantic Ocean , Calibration , Cosmic Radiation , Equipment Design , Particle Accelerators , Solar Activity , South America , Spacecraft/instrumentation , Switzerland